3M™ Attest™ Mini Auto-Reader, 490M, 1 Each/Case

  • 3M ID 7100215093
  • UPC 00707387790707

24 minute biological indicator result

4-Well, Dual Auto-reader designed for use with 3M™ Attest™ Biological Indicators 1491, 1492V and 1295. Sterilization cycles must align with the biological indicator's indications for use. See the biological indicator IFU

Extra-large, intelligent display with time-to-result countdown feature. Display can be seen from a distance for easier monitoring

View more details
Frequently viewed resources
PDF (1) Copy 26User Instructions (PDF, 13MB)

Details

Highlights
  • 24 minute biological indicator result
  • 4-Well, Dual Auto-reader designed for use with 3M™ Attest™ Biological Indicators 1491, 1492V and 1295. Sterilization cycles must align with the biological indicator's indications for use. See the biological indicator IFU
  • Extra-large, intelligent display with time-to-result countdown feature. Display can be seen from a distance for easier monitoring
  • Small footprint - takes up less counter-top space. Ideal size for medical and dental clinics and surgery centers
  • Connect to a PC using supplied USB cable to use the Attest Connect Auto-reader Application for easy documentation and printing of BI results, access to historical records, and firmware updates

The 3M™ Attest™ Mini Auto-reader 490M has 4 wells, and is designed to incubate and automatically read 3M™ Attest™ Biological Indicators 1295, 1491, and 1492V at 60°C for a final negative fluorescence reading at 24 minutes. Other biological indicators (BIs) are not compatible with this device and cannot be used.

This 24 minute Dual Auto reader features Any Well technology which means Attest™ 1491 or 1492V BIs and associated challenge packs (for steam) or Attest™ 1295 BIs  (for VH2O2 sterilization) can be incubated in any well of the Auto reader at the same time. Includes USB cable for Attest™ Connect Auto-reader application.

Specifications

Biological Indicator System

Super Rapid

Brands

Attest™

Catalog Number

490M

Incubation Period

24 Minute

Indicator Compatibility

1295, 1491, 1492V

Maximum Temperature (Celsius)

60 ℃

Number of Wells

4

Product Type

Incubator

Sterilization Method

Steam, Hydrogen Peroxide

Total Units per Case

1 per Case