1. Malaysia
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-III Termination Kit 7625-T-95, Tape/Wire/UniShield® Shielding, 5-8.7 kV, 3/kit, Indoor

3M™ Cold Shrink QT-III Termination Kit 7625-T-95, Tape/Wire/UniShield® Shielding, 5-8.7 kV, 3/kit, Indoor

  • 3M ID 7000133173

Provides a void-free seal to tape shield, wire shield and UniShield® power cables

High dielectric-constant material regulates the distribution of electric field stress

Suitable for indoor applications

View more details

Details

Highlights
  • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for indoor applications
  • Termination has 1.05 to 1.80-in insulation O.D
  • Accommodates wire sizes of 700 to 1500 kcmil at 5kV, 600 to 1250 kcmil at 8 kV
  • Non-tracking, molded, silicone rubber insulation offers durability
  • Withstands voltages of 5 to 35kV and is 95kV BIL-rated
  • Includes 3 non-skirted, 1-piece, 3-phase, cold shrink terminations
  • IEEE Standard 48 Class 1 Approved for indoor and weather-protected applications

3M™ Cold Shrink QT-III 7620-T & 7690-T Series Termination Kit includes 3 non-skirted, 1-piece, 3-phase terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric-constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.

3M™ Cold Shrink QT-III 7620-T & 7690-T Series Termination Kit is designed for terminating solid dielectric-shielded, medium voltage cables. The UV stable, track-resistant, silicone rubber insulation of the termination has a hydrophobic property and offers a long-lasting service life. The lower surface stress, high dielectric-constant material offers an optimized BIL performance while ensuring a leak-proof, compact fit. IEEE Standard 48 Class 1 Approved for indoor and weather-protected applications. Conductor Size Range for · 5 kV: 700-1500 kcmil · 8 kV: 600-1250 kcmil

Typical Properties

BIL

95 kV

Brands

3M™

Breakout Boot

No

Cable Insulation Outside Diameter Range (metric)

26.7 - 45.7 mm

Case Quantity

1

Indoor/Outdoor

Indoor Non-skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (metric)

26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm

Insulation Rejacketing

No

Lug/Stem Connector Included in Kit

No

Number of Conductors

1

Product Series

7620-T

Shielding Type

Tape Shield, Wire Shield, UniShield®

Units per Case

3.0

Voltage

5 kV, 8 kV

Voltage Application

Medium Voltage

Resources

Product Technical Illustrations

(POSTSCRIPT, 243KB)