1. Malaysia
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-III Silicone Rubber Termination 7654-S-HSG-4 (High-Amp), Longitudinally Corrugated and Wire Over Tape, 5-25/28 kV, 0.83-1.53 in (38,9-58,9 mm) Cable Insul. O.D., 1 termination/kit

3M™ Cold Shrink QT-III Silicone Rubber Termination 7654-S-HSG-4 (High-Amp), Longitudinally Corrugated and Wire Over Tape, 5-25/28 kV, 0.83-1.53 in (38,9-58,9 mm) Cable Insul. O.D., 1 termination/kit

  • 3M ID 7000132648

Provides a void-free seal to tape shield, longitudinally corrugated shield and wire-over-tape shield power cables

High dielectric-constant material regulates the distribution of electric field stress

Suitable for outdoor applications

View more details

Details

Highlights
  • Provides a void-free seal to tape shield, longitudinally corrugated shield and wire-over-tape shield power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor applications
  • Termination has 0.83 to 1.53-in insulation O.D
  • Accommodates wire sizes of 500 to 750 kcmil at 5kV, 350 to 700 kcmil at 8 kV, 4/0 AWG to 500 kcmil at 15kV, 2/0 AWG to 250 kcmil at 25/28 kV
  • Unique step-core design and silicone sealing compounds enable easier installation
  • Withstands voltages of 5 to 35kV and is 150 kV BIL-rated
  • Includes a single-phase, cold shrink termination
  • IEEE Approved

3M™ Cold Shrink QT-III 7650-S-HSG & 7660-S-HSG Series Termination Kit includes a single-phase, high-fault current termination. It ensures a pliable, tight seal for tape shield, longitudinally corrugated shield and wire-over-tape shield power cables. The conjunction of high dielectric-constant material and silicone sealing compounds allow the termination to withstand voltages of 5 to 35kV.

3M™ Cold Shrink QT-III 7650-S-HSG & 7660-S-HSG Series Termination Kit is designed for terminating medium voltage, solid dielectric-shielded power cables. The UV stable, track- and erosion-resistant construction makes the termination suitable for outdoor applications. The lower surface stress, high dielectric-constant material provides an optimized BIL performance while ensuring a leak-proof, compact fit. IEEE Approved. Conductor Size Range for · 5 kV: 500-750 kcmil · 8 kV: 350-700 kcmil · 15 kV: 4/0 AWG-500 kcmil · 25/28 kV: 2/0 AWG-250 This termination is compatible with the following lugs: QL2-A-2-250, for conductor range: 2/0 AWG-250 kcmil (25/28kV) QL2-A-4/0-600, for conductor range: 4/0 AWG-250 kcmil (25/28kV) QL2-A-1/0-350, for conductor range: 4/0 AWG-250 kcmil (15kV), 2/0 AWG-250 kcmil (25/28kV)

Typical Properties

BIL

150 kV

Brands

3M™

Breakout Boot

No

Cable Insulation Outside Diameter Range (metric)

21.1 - 38.9 mm

Case Quantity

1

Compatible Lug

QL2-A-2-250, QL2-A-1/0-350, QL2-A-4/0-600

Indoor/Outdoor

Outdoor Skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (metric)

21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm

Insulation Rejacketing

No

Lug/Stem Connector Included in Kit

No

Number of Conductors

1

Number of Skirts

4

Product Series

7650-S-HSG, 7650-S

Shielding Type

Longitudinally Corrugated (LC), Tape Shield, Wire-Over-Tape Shield

Voltage

5 kV, 8 kV, 15 kV, 25 kV

Voltage Application

Medium Voltage